Russian versionPDF Version for print
    • Hosted by ORC

Directional Couplers HO-5, HO-7, HO-10, HO-15, HO-20 400-490 MHz

Print pages (PDF 43 kb)
Electrical specifications
Model HO-5 HO-7 HO-10 HO-15 HO-20
Operating frequency band, MHz 400-490 400-490 400-490 400-490 400-490
Version -5 dB coupler -7 dB coupler -10 dB coupler -15 dB coupler -20 dB coupler
Attenuation, dB 1-3 (see. Schematical diag.) -2.3 ± 0.1 -1 ± 0.05 -0.5 ± 0.05 -1 ± 0.05 -1 ± 0.05
Attenuation, dB 1-2 (see. Schematical diag.) -5 ±0.2 -7 ±0.3 -10 ± 0.5 -15 -20
VSWR, not more than 1.3 1.3 1.3 1.3 1.3
Power of Load, W 0.1 0.1 0.1 0.1 0.1
Power no more, W 100 100 100 100 100
Impedance, Ohm 50 50 50 50 50
Temperature range, °C From -20 to +40 From -20 to +40 From -20 to +40 From -20 to +40 From -20 to +40
Mechanical specifications
Model HO-5 HO-7 HO-10 HO-15 HO-20
Weight, kg 0.27 0.27 0.27 0.27 0.27
Connectors N-female N-female N-female N-female N-female
Application Indoor Indoor Indoor Indoor Indoor
Dimensions, mm 34x51x150 34x51x150 34x51x150 34x51x150 34x51x150

Directional couplers are designed for construction of chain-structured antenna and feeder transmission lines on such radio fixation objects as subways, underground garages, high-rise buildings, sea ships, etc.


Directional couplers make it possible to partially withdraw energy from the feeder and service a small part of a subway or a room by means of a local antenna. Due to a wide service band, the directional couplers can be used in professional trunking communications of analog and digital standards (for instance, APCO25 and TETRA), and also, together with CDMA repeaters.

Schematical diagram


Isolation between input to load HO-5
 
Insertion losses in to out HO-5
 
In/Out ratio HO-5
 
Isolation between input to load HO-7
 
Insertion losses in to out HO-7
 
In/Out ratio HO-7
 
Isolation between input to load HO-10
 
Insertion losses in to out HO-10
 
In/Out ratio HO-10
 
Isolation between input to load HO-15
 
Insertion losses in to out HO-15
 
In/Out ratio HO-15
 
Isolation between input to load HO-20
 
Insertion losses in to out HO-20
 
In/Out ratio HO-20